Uploaded image for project: 'eCQM Issue Tracker'
  1. eCQM Issue Tracker
  2. CQM-4638

CMS145v9 | QRDA III | 2021 Specs

XMLWordPrintable

    • Icon: None None
    • Resolution: Answered
    • Icon: Moderate Moderate
    • None
    • None
    • Hide
      Thank you for your inquiry specific to CMS145v9- Coronary Artery Disease (CAD): Beta-Blocker Therapy-Prior Myocardial Infarction (MI) or Left Ventricular Systolic Dysfunction (LVEF <40%). After reviewing your test case scenario and conducting additional testing, we have confirmed that the measure logic, as currently written, will erroneously include the patient in both populations, as the logic currently does not consider LVSDFindings that start before the end of the second qualifying encounter. While we will look to implement a solution to this discrepancy, there is currently no solution. We greatly appreciate you bringing this issue to our attention.
      Show
      Thank you for your inquiry specific to CMS145v9- Coronary Artery Disease (CAD): Beta-Blocker Therapy-Prior Myocardial Infarction (MI) or Left Ventricular Systolic Dysfunction (LVEF <40%). After reviewing your test case scenario and conducting additional testing, we have confirmed that the measure logic, as currently written, will erroneously include the patient in both populations, as the logic currently does not consider LVSDFindings that start before the end of the second qualifying encounter. While we will look to implement a solution to this discrepancy, there is currently no solution. We greatly appreciate you bringing this issue to our attention.

      Has Cypress fully completed update to 2021 specifications for CMS145?
      We have noticed test patients which meet denominator for CMS145A also expected to be in Denominator for CMS145B.
       
      Per 2021 specifications if patient meets Denominator for CMS145A, they cannot meet denominator for CMS145B. Which is causing false failures when we validate our internally generated QRDA III files vs Cypress expected.
       
      Uploading the Cypress error message with QRDA III XML.

        1. CMS145 Error 1.JPG
          87 kB
          Jitin G Pais
        2. CMS145 Error 2.JPG
          107 kB
          Jitin G Pais
        3. Measure Guidance.JPG
          97 kB
          Jitin G Pais
        4. QRDA3_15722_Judith_Holland_CMS145_2021_1545561403_052343522.xml
          117 kB
          Jitin G Pais
        5. screencapture-bonnie-healthit-gov-2021-05-27-09_27_21.pdf
          1.67 MB
          David Czulada

            edave Mathematica EC eCQM Team
            jitin.pais Jitin G Pais
            Votes:
            1 Vote for this issue
            Watchers:
            8 Start watching this issue

              Created:
              Updated:
              Resolved: