Has Cypress fully completed update to 2021 specifications for CMS145?
We have noticed test patients which meet denominator for CMS145A also expected to be in Denominator for CMS145B.
Per 2021 specifications if patient meets Denominator for CMS145A, they cannot meet denominator for CMS145B. Which is causing false failures when we validate our internally generated QRDA III files vs Cypress expected.
Uploading the Cypress error message with QRDA III XML.
- is duplicated by
-
CYPRESS-2258 CMS 145 Denominator 2 logic clarification
- Closed
- relates to
-
EKI-12 CMS145v9/CMS145v10 – CQL logic “Qualifying CAD Encounter and Prior MI” doesn’t include LVSD that starts prior to the second qualifying encounter, which may cause patients with both prior MI and LVSD to be erroneously included in both populations 1 and 2.
- Done