Uploaded image for project: 'QRDA Issue Tracker'
  1. QRDA Issue Tracker
  2. QRDA-915

RelaventDatetime concept export

XMLWordPrintable

    • Icon: QRDA-I Standard QRDA-I Standard
    • Resolution: Answered
    • Icon: Moderate Moderate
    • None
    • None
    • How do we correctly export patients with multiple measures using relaventDatetime and relaventPeriod
    • Medisolv
    • Michael Pickens
    • 4106107904
    • Hide
      Reference QKI-2 for resolution.
      Show
      Reference QKI-2 for resolution.

      A QDM "Procedure, Performed" has both a relaventDatetime and a relaventPeriod property.  Per instruction in QRDA-895 the measure logic gets to pick how the effective time is exported.  E.g. if the measure uses the relevantPeriod property it should be emitted with effectiveTime/low and effectiveTime/high values.  But what happens if a patient qualifies for two measures, one that looks for relevantPeriod and one that looks for relevantDatetime?  Should we emit the procedure twice?

      There are several QDM elements that have this behavior, so this is a general question.

      Assessment, Performed

      Device, Applied

      Diagnostic Study, Performed

      Intervention, Performed

      Medication, Active

      Medication, Dispensed

      Physical Exam, Performed

      Procedure, Performed

      Substance, Administered

            yanheras Yan Heras
            mpickens Michael Pickens
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

              Created:
              Updated: