Uploaded image for project: 'CYPRESS Issue Tracker'
  1. CYPRESS Issue Tracker
  2. CYPRESS-1119

Cypress v3.2 does not seem to generate input QRDA Cat 1 documents correctly

XMLWordPrintable

    • Icon: Question Question
    • Resolution: Delivered
    • Icon: Moderate Moderate
    • Logic affecting more than 1 eCQM

      We downloaded and setup Cypress v3.2 on 8/4. When we started testing we noticed multiple measures failing.

      On investigation, we noticed that the input QRDA Cat I that Cypress was generating were missing multiple data points. The same patient when we drill-down to look at the patient details had information (e.g. a condition or a procedure) that was missing in the QRDA file downloaded. "Get known good results" produced a QRDA file that's different from the one in the input.When we say the above, we have accounted for duplicate files where clinical data is spread across 2 or more files.

      I have attached an example (7_Shirley_Mathis.xml is from "known good results" where as "13_Shirley_Mathis" and "14_Shirley_Mathis" are the original input test data set).

      I looked through the open issues, but didn't find anyone else having such issues. Not sure, if we are missing something altogether. We initially setup a VM instance, and also followed it up with a full-blown custom installation to see if we are missing anything out.

            dczulada David Czulada
            sgnana Gnana Krishnan
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

              Created:
              Updated:
              Resolved: