Annual Update
-
Resolution: Delivered
-
Minor
-
None
-
Tamara Bailey
-
520.753.4324
-
Midas+
-
In the denominator logic there exists:
AND: "Occurrence A of Device, Applied: Hospital Measures-Indwelling urinary catheter (start datetime, anatomical structure: 'Hospital Measures-Urethra')" during "Occurrence A of Encounter, Performed: Encounter Inpatient"
Per the measure logic guidance, in order for something to be "during" an encounter, it has to have a start and end date time, since you're specifically looking at the start datetime here, the logic should say:
AND: "Occurrence A of Device, Applied: Hospital Measures-Indwelling urinary catheter (start datetime, anatomical structure: 'Hospital Measures-Urethra')" STARTS during "Occurrence A of Encounter, Performed: Encounter Inpatient"