Uploaded image for project: 'eCQM Issue Tracker'
  1. eCQM Issue Tracker
  2. CQM-2930

CMS117/NQF 0038 Numerator- Clarification needed for Seropositive test result for the antigen as it is there in Guidance but Not Present in Data Criteria

XMLWordPrintable

    • CMS 137/NQF 0004 2018 eCQM eSpec states one thing in the Description and another in the configuration section of eSpec for the Numerator.
    • Varun Mishra
    • 8197222347
    • Allscripts Healthcare Solutions
    • Please clarify whether seropositive test result for the antigen has to be taken into consideration Or NOT.
    • Hide
      You should not have to include it in the configuration. We removed the Seropositive Grouping Value Set from the measure because we put in the actual tests and results that indicate someone is seropositive. For example: for Hepatitis A, there is a line of logic allowing for a positive antigen result to meet the numerator "Laboratory Test, Performed: Anti Hepatitis A IgG Antigen Test (result: Positive Finding)". Here is the associated value set: "Laboratory Test, Performed: Anti Hepatitis A IgG Antigen Test" using "Anti Hepatitis A IgG Antigen Test Grouping Value Set (2.16.840.1.113883.3.464.1003.198.12.1033)"
      Show
      You should not have to include it in the configuration. We removed the Seropositive Grouping Value Set from the measure because we put in the actual tests and results that indicate someone is seropositive. For example: for Hepatitis A, there is a line of logic allowing for a positive antigen result to meet the numerator "Laboratory Test, Performed: Anti Hepatitis A IgG Antigen Test (result: Positive Finding)". Here is the associated value set: "Laboratory Test, Performed: Anti Hepatitis A IgG Antigen Test" using "Anti Hepatitis A IgG Antigen Test Grouping Value Set (2.16.840.1.113883.3.464.1003.198.12.1033)"
    • CMS117v6/NQF0038
    •  I am unable to complete configuration of the 2018 CMS 117/NQF 0038 measure until this question is answered.

      For CMS 117/ NQF 0038
      guidance speaks as below
      For the MMR, hepatitis B, VZV and hepatitis A vaccines, numerator inclusion criteria include: evidence of receipt of the recommended vaccine; documented history of the illness; or, a seropositive test result for the antigen.
      Numerator Description speaks
      Children who have evidence showing they received recommended vaccines, had documented history of the illness, had a*+ seropositive test result,+* or had an allergic reaction to the vaccine by their second birthday

      But,
      "Seropositive Grouping Value Set (2.16.840.1.113883.3.464.1003.110.12.1054)" is NOT in version 6 of CMS 117/NQF 0038.

      Please clarify whether "Seropositive Grouping Value Set" has to be Included while doing configuration or Not ?

            edave Mathematica EC eCQM Team
            vmishra Varun Mishra (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: