CMS159v4 and CMS160v4: snomed code dead not in value set

XMLWordPrintable

    • Icon: EC eCQMs - Eligible Clinicians EC eCQMs - Eligible Clinicians
    • Resolution: Answered
    • Icon: Minor Minor
    • Measure
    • None
    • Elissa Chandler
    • 267-725-5354
    • NextGen Healthcare
    • Hide
      In answer to your question regarding the SNOMED code 419099009, yes, measure developers should use this code for the QDM element Patient Characteristic Expired.
       
      Patient Characteristic Expired was fixed to SNOMED-CT® code 419099009 (Dead) with the release of Quality Data Model version 4.1.

      Similarly, Patient Characteristic Birthdate was fixed to LOINC code 21112-8 (Birth date).

      Because both the "expired" and "birthdate" codes are locked into the MAT, they do not appear in value sets imported into the MAT, but the code does appear in the xml.

      If the failure of these codes to appear in the VSAC is problematic, we encourage you to reopen, create a new ticket or comment on this one.
      Show
      In answer to your question regarding the SNOMED code 419099009, yes, measure developers should use this code for the QDM element Patient Characteristic Expired.   Patient Characteristic Expired was fixed to SNOMED-CT® code 419099009 (Dead) with the release of Quality Data Model version 4.1. Similarly, Patient Characteristic Birthdate was fixed to LOINC code 21112-8 (Birth date). Because both the "expired" and "birthdate" codes are locked into the MAT, they do not appear in value sets imported into the MAT, but the code does appear in the xml. If the failure of these codes to appear in the VSAC is problematic, we encourage you to reopen, create a new ticket or comment on this one.
    • CMS159v4/NQF0710, CMS160v4/NQF0712
    • High impacts measures development

      QUESTION: CMS159v4 and CMS160v4: dead:

      According to the attached Technical Release Notes pg 125 for CMS 159v4 and CMS 160v4 it says:

      "The new QDM element 'Patient Characteristic Expired' represents SNOMED code 419099009 (Dead). It replaces the previously used QDM 'Patient Characteristic Expired: Deceased' using 'Deceased Grouping Value Set (2.16.840.1.113883.3.67.1.101.11.721)".

      However, the new SNOMED code 419099009 (Dead) is not included in the 2016 CQM Value Set spreadsheet for these 2 measures. And further the old SNOMED codes for deceased have been removed from the value set.

      Should our measures developers use the SNOMED code 419099009 (Dead) included in the technical release notes for CMS159v4 and CMS160v4?

      Please advise.

      Thank you.

        1. EHandEPTRNs.pdf
          893 kB
          Elissa Chandler

            lwisham Lindsey Wisham
            elissa Elissa Chandler (Inactive)