Bug/Issue
-
Resolution: Deferred for Future Release
-
Blocker
-
None
-
None
-
MADiE
-
Not Applicable
-
CMS133v13 - Cataracts: 20/40 or Better Visual Acuity within 90 Days Following Cataract Surgery
-
QDM/CQL
-
MADiE 2.0.4
-
Yes
Description: unable to export QRDA for CMS133v13 - 500 error code.
STR:
1. Madie/Measures/Find "CMS133v13 - Cataracts: 20/40 or Better Visual Acuity within 90 Days Following Cataract Surgery" measure or create a new CMS133 measure.
2. Test cases tab/ Run tests/Export Test cases/select QRDA
Actual result: the error message is displayed "Unable to Export QRDA. Please try again. If the issue continues, please contact helpdesk." See the screenshot for more info.
Expected result: a zip file is exported.
Notes:
1. All other measures work as expected.
2. Another user tried to reproduce and had the same problem.
CMS133v13 - Cataracts: 20/40 or Better Visual Acuity within 90 Days Following Cataract Surgery/QDM v5.6
https://madie.cms.gov/measures/66b3e0d5e2eef6161d6999d0/edit/details/
- is cloned by
-
MADIE-2079 Madie/CMS11161v3/Unable to Export QRDA
- Closed
- is duplicated by
-
MADIE-2020 Getting a 'Unable to Export QRDA' error message for CMS108 test cases
- Closed
-
MADIE-2038 Not able to export test cases in QRDA format
- Closed