-
Question
-
Resolution: Resolved
-
Moderate
-
CMS0136v12
-
Cypress v7.1.0
During our Cypress Cert Testing for CMS136v12 which is to verify that C1, C2 and C3 are Qualifying or Not, Cypress validation is throwing error due to count mismatch.
Expectation as per CMS spec Follow-Up Care for Children Prescribed ADHD Medication (ADD) 12.0.000 (healthit.gov) –
The patient should qualify for the numerator condition, and it is qualifying in our application, whereas Cypress is not expecting it to qualify.
Attached example (Encounter.xml and MedicationOrder.xml) show:
the Encounter low value as 20230115170000 and high value as 20230115180000
the Medication effectivetime low value as 20230115180000 and high value as 20230115180000
Below screenprint is the CQL Logic
interval includes medication author/relavant datetime +30 days
- is cloned by
-
CYPRESS-2573 Cypress Cert Validation - Count Mismatch error CMS136
- Closed
- relates to
-
CQM-6421 Cypress Cert Validation - Count Mismatch error CMS136v12
- Closed