Bug/Issue
-
Resolution: Resolved
-
Moderate
-
Cypress v7.0.2
-
Question
Hi Team,
We were testing CMS 334 in Cypress for C2 and C3. There was one scenario (attached is the input QRDA I file) in which Cypress is expecting to qualify for the Numerator condition. We observed that the patient data provided in Cypress mentions the existence of 3 procedures as per the screenshot below.
Input QRDA zip file has only one Procedure Performed entry with two codes, one mentioned in the code tag and the other in the translation tag. We went through the IG and Schematron and the sample file as well but could not find any reference of translation being used for the procedure performed.
Can you please clarify this?
Thanks,
Auryl
- relates to
-
CYPRESS-2463 CMS334_Code & translation code
- Closed
-
CYPRESS-2490 CMS 334 Master Patient 1 (RV 1) OB Numerator
- Closed