Reason for Device, Order Not Done is not appropriately defined in the QRDA CAT I file generated from Cypress 3.2.3

XMLWordPrintable

    • Icon: Bug/Issue Bug/Issue
    • Resolution: Resolved
    • Icon: Moderate Moderate
    • Reason should be within the device, order template
    • Question Certification Question

      Attached word document provides the details of the issue.

      I have also attached the test file generated from Cypress 3.2.3.

      This issue has been discussed in the JIRA item Cypress-1313. However, it seems the issue is still present within Cypress 3.2.3? So I'm creating this item to understand how we need to address this issue for our certification testing. 