HH-RF Intubation timing

XMLWordPrintable

    • Type: Hosp Inpt eCQMs - Hospital Inpatient eCQMs
    • Resolution: Resolved
    • Priority: Moderate
    • Component/s: None
    • None
    • crystal rios
    • crio
    • Penn State Health
    • Hide
      Thank you for your inquiry regarding CMS1218, Hospital Harm - Postoperative Respiratory Failure. The measure does not consider the continuation of non-invasive oxygen therapy alone to be evidence of postoperative respiratory failure. Instead, the measure uses documentation of non-invasive oxygen therapy, like room air, nasal cannula, face masks, or continuous or intermittent positive airway pressure devices, to help distinguish newly initiated mechanical ventilation from continued postoperative mechanical ventilation. The measure's numerator identifies postoperative respiratory failure based on either (1) initiation of mechanical ventilation or intubation outside a procedural area within 30 days after the end of the first operating room (OR) procedure, or (2) prolonged mechanical ventilation lasting more than 48 hours after the last OR procedure.

      In the scenario described, transitioning from invasive mechanical ventilation to CPAP, humidified oxygen, nasal cannula, and ultimately room air would not, by itself, satisfy the numerator criteria. However, if the patient remained intubated or mechanically ventilated for more than 48 hours after the last OR procedure, the hospitalization could meet the numerator criteria, depending on the timing and documentation of respiratory support.

      [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
      Show
      Thank you for your inquiry regarding CMS1218, Hospital Harm - Postoperative Respiratory Failure. The measure does not consider the continuation of non-invasive oxygen therapy alone to be evidence of postoperative respiratory failure. Instead, the measure uses documentation of non-invasive oxygen therapy, like room air, nasal cannula, face masks, or continuous or intermittent positive airway pressure devices, to help distinguish newly initiated mechanical ventilation from continued postoperative mechanical ventilation. The measure's numerator identifies postoperative respiratory failure based on either (1) initiation of mechanical ventilation or intubation outside a procedural area within 30 days after the end of the first operating room (OR) procedure, or (2) prolonged mechanical ventilation lasting more than 48 hours after the last OR procedure. In the scenario described, transitioning from invasive mechanical ventilation to CPAP, humidified oxygen, nasal cannula, and ultimately room air would not, by itself, satisfy the numerator criteria. However, if the patient remained intubated or mechanically ventilated for more than 48 hours after the last OR procedure, the hospitalization could meet the numerator criteria, depending on the timing and documentation of respiratory support. [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
    • Not measure related
    • Not measure related
    • CMS0071v15
    • CMS0071v14
    • CMS0071v13

      I am new to HH-RF.  I have a question regarding a patient who leaves the OR intubated and noninvasive oxygen therapy starts sometime while on the floor.

      Example: patient leaves the OR intubated→CPAP→humidified→nasal cannula→ Room Air.   

      Is this considered respiratory failure due to the continuation of non-ivasive oxygen therapy? I'm a little confused? Thank you.

            Assignee:
            Mathematica EH eCQM Team
            Reporter:
            Crystal Rios
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: