HH AKI eGFR calculations

XMLWordPrintable

    • Type: Hosp Inpt eCQMs - Hospital Inpatient eCQMs
    • Resolution: Resolved
    • Priority: Moderate
    • Component/s: None
    • None
    • Traci
    • 239-289-6365
    • NCH
    • Hide
      Thank you for your question regarding CMS832v3, Hospital Harm – Acute Kidney Injury.

      As described in the Definition section of the CMS832v3 measure specification, the estimated glomerular filtration rate (eGFR) is calculated using the index serum creatinine, patient sex, and patient age according to the CKD-EPI Creatinine Equation.

      The CMS832v3 measure logic does not specify an additional rounding step in the eGFR calculation or the index eGFR denominator exclusion logic. Accordingly, for measure calculation and evaluation, implementers should use the calculated eGFR value without adding a separate rounding step when processing these measure criteria.

      For example, when evaluating the denominator exclusion for ‘Encounter with Index eGFR Less Than 60’, a calculated value of 59.9 mL/min is below the threshold, whereas 60.0 mL/min is not.

      For patient reporting, the eCQM specification does not establish a separate policy governing how laboratories should display eGFR results when reporting results to patients. Therefore, the measure-specific clarification should not be interpreted as directing laboratories to disregard other applicable guidance for patient-facing laboratory result reporting.

      [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
      Show
      Thank you for your question regarding CMS832v3, Hospital Harm – Acute Kidney Injury. As described in the Definition section of the CMS832v3 measure specification, the estimated glomerular filtration rate (eGFR) is calculated using the index serum creatinine, patient sex, and patient age according to the CKD-EPI Creatinine Equation. The CMS832v3 measure logic does not specify an additional rounding step in the eGFR calculation or the index eGFR denominator exclusion logic. Accordingly, for measure calculation and evaluation, implementers should use the calculated eGFR value without adding a separate rounding step when processing these measure criteria. For example, when evaluating the denominator exclusion for ‘Encounter with Index eGFR Less Than 60’, a calculated value of 59.9 mL/min is below the threshold, whereas 60.0 mL/min is not. For patient reporting, the eCQM specification does not establish a separate policy governing how laboratories should display eGFR results when reporting results to patients. Therefore, the measure-specific clarification should not be interpreted as directing laboratories to disregard other applicable guidance for patient-facing laboratory result reporting. [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
    • Not measure related
    • Not measure related
    • CMS0832v3
    • CMS1028v3
    • CMS0071v13

      Out Lab wants a definitive response from CMS that for PATIENT REPORTING that they are to NOT follow Kidney foundation guidelines and NOT round the final result.  Again, they are fine with using 143.704 within the calculation (142x1.012) but they want to round the final result per guidelines they follow from Kidney Foundation

            Assignee:
            Mathematica EH eCQM Team
            Reporter:
            Traci Corsones
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: