CMS832v3 Hospital Harm - Acute Kidney Injury - Possible False Read

XMLWordPrintable

    • Type: Hosp Inpt eCQMs - Hospital Inpatient eCQMs
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Hide
      Thank you for your inquiry regarding CMS832v3, Hospital Harm - Acute Kidney Injury.

      The measure specification does not provide an exclusion or adjustment for a serum creatinine result that is suspected to be erroneous because of a faulty blood draw or laboratory error.

      For the index serum creatinine, the measure uses the lowest serum creatinine value within the first 24 hours of the encounter; if no value is available during that period, it uses the first value within 48 hours. Therefore, if both results occur within the first 24 hours, the lower qualifying result would be used as the index serum creatinine.

      For numerator assessment, the measure evaluates qualifying serum creatinine results according to the specified timing and thresholds for evidence of a 2 times increase. It does not contain logic to disregard a qualifying serum creatinine that is followed by another serum creatinine that is normal. Such a determination would therefore need to be addressed through the hospital's underlying laboratory/EHR data processes rather than through an exception in the measure logic.

      We appreciate this feedback and will take this into consideration during a future Annual Update of the measure.

      [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
      Show
      Thank you for your inquiry regarding CMS832v3, Hospital Harm - Acute Kidney Injury. The measure specification does not provide an exclusion or adjustment for a serum creatinine result that is suspected to be erroneous because of a faulty blood draw or laboratory error. For the index serum creatinine, the measure uses the lowest serum creatinine value within the first 24 hours of the encounter; if no value is available during that period, it uses the first value within 48 hours. Therefore, if both results occur within the first 24 hours, the lower qualifying result would be used as the index serum creatinine. For numerator assessment, the measure evaluates qualifying serum creatinine results according to the specified timing and thresholds for evidence of a 2 times increase. It does not contain logic to disregard a qualifying serum creatinine that is followed by another serum creatinine that is normal. Such a determination would therefore need to be addressed through the hospital's underlying laboratory/EHR data processes rather than through an exception in the measure logic. We appreciate this feedback and will take this into consideration during a future Annual Update of the measure. [For follow-up questions submitted more than 30 days after the "Solution Posted On" date, please submit a new Jira ticket.]
    • Not measure related
    • Not measure related
    • CMS0832v3
    • CMS0832v1
    • CMS0071v13
    • When creatinine is repeated in few hours and the reading in in normal range. Possibility of false labs due to faulty draw.

          Assignee:
          Mathematica EH eCQM Team
          Reporter:
          Diane Huntley
          Votes:
          0 Vote for this issue
          Watchers:
          3 Start watching this issue

            Created:
            Updated:
            Resolved:
            Solution Posted On: