• Type: Hosp Inpt eCQMs - Hospital Inpatient eCQMs
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Hide
      Thank you for your question regarding CMS826v3, Hospital Harm - Pressure Injury. If a patient has a qualifying stage 2, stage 3, stage 4, deep tissue, or unstageable pressure injury with a Present on Admission (POA) indicator of "Y", then the inpatient hospitalization for this patient would be excluded from the measure's denominator. Once an inpatient hospitalization is excluded from the measure's denominator, any new pressure injuries that the patient develops later in the hospitalization (i.e., those with a POA indicator of "N") would not qualify the patient's hospitalization for the measure's numerator.
      Show
      Thank you for your question regarding CMS826v3, Hospital Harm - Pressure Injury. If a patient has a qualifying stage 2, stage 3, stage 4, deep tissue, or unstageable pressure injury with a Present on Admission (POA) indicator of "Y", then the inpatient hospitalization for this patient would be excluded from the measure's denominator. Once an inpatient hospitalization is excluded from the measure's denominator, any new pressure injuries that the patient develops later in the hospitalization (i.e., those with a POA indicator of "N") would not qualify the patient's hospitalization for the measure's numerator.
    • Not measure related
    • CMS0826v4
    • CMS0826v3
    • CMS0826v2
    • CMS0071v13

      We are seeking clarification regarding CMS826v3 Hospital Harm - Pressure Injury logic in encounters involving multiple pressure injuries with differing POA indicators.

      Based on prior guidance, we understand the measure evaluates the patient's entire hospitalization and that if a qualifying Stage 2, 3, 4, or unstageable pressure injury diagnosis has a POA indicator of "Y" or "W," the encounter meets denominator exclusion criteria regardless of when the POA status was assigned during the hospitalization.

      However, we are attempting to clarify how the measure logic should behave when multiple qualifying pressure injuries exist within the same encounter.

      Example scenario:

      • Patient has one qualifying pressure injury coded with POA = Y
      • Patient also has a separate qualifying pressure injury coded with POA = N 
      • Does the logic stop at Y or should it note ther is a N too? 