patients counted in numerator when they have exceptions/ exclusions not outlined within the measure Patient delays and ECMO
1.
Please consider exceptions for “patient related delay”. This is consistent with how the American College of Cardiology National Cardiac Data Registry (ACC NCDR) operates.
If , for example, a patient needs time to decide if they want a cath or wants to wait for family to arrive to help make a decision, this is considered patient related delay and excludes the case from reporting since the time to PCI is then skewed. There are other examples of this type of delay to get consent to go for the procedure such as needing to have extended conversation about changing DNR/DNI status or prognosis in light of other co-morbid conditions that can affect outcomes. Other patient related delay currently not captured for an exception is when the STEMI occurs yet another procedure or test must first be performed to evaluate for the safety to take the patient for a PCI. Also is the circumstance for which hemodynamic instability of any sort must be managed before the patient can safely go for an invasive procedure.
2.
Please consider adding exceptions/exclusions for door in door out times similar to Lytic and PCI. Patient related delay can cause delay in moving a patient to transport. This would include any delay in deciding whether they will consent to a procedure, hemodynamic instability which needs to be managed before transport and any test or therapy that would need to be completed prior to getting the patient transported safely.
3.
Please consider an exclusion for door in door out within 45 minutes to include the circumstance of not having an EMS resource immediately available. If you intend to measure ED performance, the ED has no control over the operations of EMS which inconsistently is available. Sometimes there is delay because we first dispatch air and then they decline due to either weather or staffing or unavailability because they are all in use. Our hospital then has to find a ground resource who needs to travel a significant distance at times just to get to the facility. Perhaps you could consider measuring what we call our “door out ready time.” This is when all clinical treatments are completed and the patient is packed and ready to leave BUT now is waiting for transport to arrive.
4.
Please add ECMO to the circulatory assist device list.