cms996v6 eSTEMI - Clarification on PCI Contraindication Documentation Timing

XMLWordPrintable

    • Type: Hosp Outpt eCQMs - Hospital Outpatient eCQMs
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Kris Majumdar
    • 5738842373
    • University of Missouri Health Care
    • Hide
      Thank you for your inquiry regarding CMS996v6, Appropriate Treatment for ST-Segment Elevation Myocardial Infarction (STEMI) Patients in the Emergency Department (ED). Per the CQL logic, the documentation of the reason for not performing PCI must occur during the ED encounter, and not within 90 minutes of ED arrival, as shown in the logic below found in the measure’s HTML file (https://ecqi.healthit.gov/sites/default/files/ecqm/measures/CMS996-v6.3.000-QDM.html).

      ED Encounter With A Documented Reason For No PCI Performed Within 90 Minutes Of ED Arrival
        "ED Encounter With STEMI Diagnosis" EDwSTEMI
          with (["Procedure, Not Performed": "Percutaneous Coronary Intervention"] NoPCI
                where (NoPCI.negationRationale in "Patient Refusal" or NoPCI.negationRationale in "Procedure Not Indicated/Contraindicated")) PCIRefused
          such that PCIRefused.authorDatetime during EDwSTEMI.relevantPeriod

      The logic uses the authorDatetime attribute of the ["Procedure, Not Performed": "Percutaneous Coronary Intervention"] data element to indicate the datetime the negationRationale (i.e., the reason the procedure was not performed) was entered into the clinical software. To meet the denominator exception criteria, the authorDatetime must be during the ED encounter relevantPeriod, which represents the period between the startTime that the encounter began (admission time) and the stopTime that the encounter ended (discharge or change in patient disposition time).

      Therefore, in the example you provided, if the contraindication is clinically identified at 2:00 AM, but is documented at 5:00 AM, the author Datetime associated with the entry would be 5:00 AM. If the ED encounter ended after 5:00 AM (e.g., 6:00 AM), then the encounter would meet the denominator exception criteria. However, if the ED encounter ends before 5:00 AM, (e.g., 4:00 AM), then the encounter would not meet the denominator exception criteria.

      Concerns regarding the timing for documenting reasons for not performing PCI have been brought up to the measure developer. CMS and the measure developer will consider expanding the time frame for the documented reason for not performing a PCI within 90 minutes of ED arrival and documented reason for not administering fibrinolytic therapy within 30 minutes of ED arrival denominator exceptions in a future annual update.
      Show
      Thank you for your inquiry regarding CMS996v6, Appropriate Treatment for ST-Segment Elevation Myocardial Infarction (STEMI) Patients in the Emergency Department (ED). Per the CQL logic, the documentation of the reason for not performing PCI must occur during the ED encounter, and not within 90 minutes of ED arrival, as shown in the logic below found in the measure’s HTML file ( https://ecqi.healthit.gov/sites/default/files/ecqm/measures/CMS996-v6.3.000-QDM.html ). ED Encounter With A Documented Reason For No PCI Performed Within 90 Minutes Of ED Arrival   "ED Encounter With STEMI Diagnosis" EDwSTEMI     with (["Procedure, Not Performed": "Percutaneous Coronary Intervention"] NoPCI           where (NoPCI.negationRationale in "Patient Refusal" or NoPCI.negationRationale in "Procedure Not Indicated/Contraindicated")) PCIRefused     such that PCIRefused.authorDatetime during EDwSTEMI.relevantPeriod The logic uses the authorDatetime attribute of the ["Procedure, Not Performed": "Percutaneous Coronary Intervention"] data element to indicate the datetime the negationRationale (i.e., the reason the procedure was not performed) was entered into the clinical software. To meet the denominator exception criteria, the authorDatetime must be during the ED encounter relevantPeriod, which represents the period between the startTime that the encounter began (admission time) and the stopTime that the encounter ended (discharge or change in patient disposition time). Therefore, in the example you provided, if the contraindication is clinically identified at 2:00 AM, but is documented at 5:00 AM, the author Datetime associated with the entry would be 5:00 AM. If the ED encounter ended after 5:00 AM (e.g., 6:00 AM), then the encounter would meet the denominator exception criteria. However, if the ED encounter ends before 5:00 AM, (e.g., 4:00 AM), then the encounter would not meet the denominator exception criteria. Concerns regarding the timing for documenting reasons for not performing PCI have been brought up to the measure developer. CMS and the measure developer will consider expanding the time frame for the documented reason for not performing a PCI within 90 minutes of ED arrival and documented reason for not administering fibrinolytic therapy within 30 minutes of ED arrival denominator exceptions in a future annual update.
    • EH
    • CMS1244v1
    • CMS0996v6
    • CMS0996v5
    • CMS0996v4
    • Imprecise denominator exception.

      Hello,

      For the eSTEMI (CMS OP-40) measure, our vendor provides the option to document a contraindication to Percutaneous Coronary Intervention (PCI), which would function as a denominator exception and remove the case from the measure. While we welcome this enhancement, we have been informed that, per CMS guidance, documentation of the contraindication must occur within 90 minutes of ED arrival and cannot be backdated. In other words, documentation entered later cannot reflect that the contraindication was identified within the initial 90-minute window.

      If this reflects CMS requirements, it presents a significant operational challenge. In the ED setting, clinical care appropriately takes precedence, and documentation is often completed afterward and backdated as part of standard practice, particularly in high-acuity cases.

      If backdating to the 90-minute window is not permitted, the recorded timestamp would frequently fall after that window, resulting in cases being retained in the denominator despite valid contraindications. This would not accurately reflect clinical decision-making or performance and could lead to misrepresentation in what is ultimately reported to CMS.

      To confirm, are we prohibited from backdating PCI contraindications to reflect when they were clinically determined within the 90-minute window?

      For example, if a patient arrives at 1:00 AM and a contraindication is clinically identified at 2:00 AM, would it be permissible to document this later, such as at 5:00 AM, while accurately reflecting the time of determination as 2:00 AM?

      Thank you for your guidance on this matter.

            Assignee:
            Mathematica EH eCQM Team
            Reporter:
            Kris Majumdar
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: