Preventive Care and Screening: Screening for Depression and Follow-Up Plan

XMLWordPrintable

    • Type: EC eCQMs - Eligible Clinicians
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Brigetta Ober
    • 317-209-6694
    • Ascension Medical Group
    • Hide
      Thank you for inquiring about CMS0002v15 (Preventive Care and Screening: Screening for Depression and Follow-Up Plan).
       
      “Not tolerated” appears to be an EHR-specific selection, and not part of the actual screening tools referenced. However, the measure has a “Medical Reason” denominator exception, which includes SNOMED CT code 407563006 (Treatment not tolerated (situation)). If the “Not tolerated” the button is selected in your EHR, AND your reporting vendor has the button mapped accordingly, AND a depression screen was not completed during the measurement period, then the patient will be considered exempt from requiring a depression screen.
       
      Excerpt from Denominator Exception section of CMS0002v15:
      "Medical Reason(s) 
      Documentation of medical reason for not screening patient for depression (e.g., cognitive, functional, or motivational limitations that may impact accuracy of results; patient is in an urgent or emergent situation where time is of the essence and to delay treatment would jeopardize the patient's health status)”
      Show
      Thank you for inquiring about CMS0002v15 (Preventive Care and Screening: Screening for Depression and Follow-Up Plan).   “Not tolerated” appears to be an EHR-specific selection, and not part of the actual screening tools referenced. However, the measure has a “Medical Reason” denominator exception, which includes SNOMED CT code 407563006 (Treatment not tolerated (situation)). If the “Not tolerated” the button is selected in your EHR, AND your reporting vendor has the button mapped accordingly, AND a depression screen was not completed during the measurement period, then the patient will be considered exempt from requiring a depression screen.   Excerpt from Denominator Exception section of CMS0002v15: "Medical Reason(s)  Documentation of medical reason for not screening patient for depression (e.g., cognitive, functional, or motivational limitations that may impact accuracy of results; patient is in an urgent or emergent situation where time is of the essence and to delay treatment would jeopardize the patient's health status)”
    • CMS0002v15
    • Patients for whom a depression screening is inappropriate, based on physical and/or mental limitations need to be removed from denominator.

      1) Will the "Not Tolerated" selection on the PHQ2/PHQ9 exclude a patient from the depression screening measure(s) if selected?

       

      2) If the "not tolerated" button does not exclude the patient from the quality measure, what action should be taken if a patient has dementia or other condition that hinders their ability to complete the PHQ2/PHQ9 accurately?