CMS165 - multiple bp reading on same day

XMLWordPrintable

    • Type: EC eCQMs - Eligible Clinicians
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Hide
      NCQA’s response:
      Thank you for your inquiry regarding CMS165v14 (2026 Performance Period). The measure numerator evaluates the most recent qualifying BP. The BP readings are not tied to a specific encounter, thus BP readings do not need to be during a visit. The criteria is further explained in the measure guidance (quoted below). "In reference to the numerator element, only blood pressure readings performed by a clinician or an automated blood pressure monitor or device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by an automated blood pressure monitor or device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the automated blood pressure monitor or device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings taken during an acute inpatient stay or an ED visit. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled". If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. Ranges and thresholds do not meet criteria for this measure. A distinct numeric result for both the systolic and diastolic BP reading is required for numerator compliance." In your example, the lowest diastolic value of 80 and the lowest systolic value of 130 recorded on 2/17/2026 will be used for numerator calculation.

      Additional guidance on qualifying blood pressure readings can be found in the measure specification's "Guidance" section. Please review the measure specification for further details about measure requirements: https://ecqi.healthit.gov/sites/default/files/ecqm/measures/CMS165-v14.0.000-QDM.html. If you have questions about reading the measure specification or understanding data requirements, you may refer to the "Guide for Reading eCQMs" for additional guidance. If you have questions regarding implementing the measure, you may refer to the "Implementation Checklist for eCQM Annual Update" for additional guidance. These resources can be found in the eCQI Resource Center: https://ecqi.healthit.gov/ep-ec?qt-tabs_ep=ecqm-resources&global_measure_group=eCQMs
      Show
      NCQA’s response: Thank you for your inquiry regarding CMS165v14 (2026 Performance Period). The measure numerator evaluates the most recent qualifying BP. The BP readings are not tied to a specific encounter, thus BP readings do not need to be during a visit. The criteria is further explained in the measure guidance (quoted below). "In reference to the numerator element, only blood pressure readings performed by a clinician or an automated blood pressure monitor or device are acceptable for numerator compliance with this measure. This includes blood pressures taken in person by a clinician and blood pressures measured remotely by electronic monitoring devices capable of transmitting the blood pressure data to the clinician. Blood pressure readings taken by an automated blood pressure monitor or device and conveyed by the patient to the clinician are also acceptable. It is the clinician’s responsibility and discretion to confirm the automated blood pressure monitor or device used to obtain the blood pressure is considered acceptable and reliable and whether the blood pressure reading is considered accurate before documenting it in the patient’s medical record. Do not include BP readings taken during an acute inpatient stay or an ED visit. If no blood pressure is recorded during the measurement period, the patient's blood pressure is assumed "not controlled". If there are multiple blood pressure readings on the same day, use the lowest systolic and the lowest diastolic reading as the most recent blood pressure reading. Ranges and thresholds do not meet criteria for this measure. A distinct numeric result for both the systolic and diastolic BP reading is required for numerator compliance." In your example, the lowest diastolic value of 80 and the lowest systolic value of 130 recorded on 2/17/2026 will be used for numerator calculation. Additional guidance on qualifying blood pressure readings can be found in the measure specification's "Guidance" section. Please review the measure specification for further details about measure requirements: https://ecqi.healthit.gov/sites/default/files/ecqm/measures/CMS165-v14.0.000-QDM.html . If you have questions about reading the measure specification or understanding data requirements, you may refer to the "Guide for Reading eCQMs" for additional guidance. If you have questions regarding implementing the measure, you may refer to the "Implementation Checklist for eCQM Annual Update" for additional guidance. These resources can be found in the eCQI Resource Center: https://ecqi.healthit.gov/ep-ec?qt-tabs_ep=ecqm-resources&global_measure_group=eCQMs
    • CMS0165v14
    • CMS0165v13
    • CMS0165v12
    • Numerator qualification for patient

      Hi There,

      For CMS165 measure, if patient has multiple bp readings on same day, measure definition describes we need to take min value recorded. In this case, it is ok to consider the Systolic ** and  ** Diastolic values from different reading to qualify the patient in numerator.

      Ex. - if patient as below reading,  minimum value for diastolic and systolic on 2/17/2026 it will be 130 and 80.

      BP reading 1 - 2/17/2026 10:30 am -  Diastolic= 80, Systolic = 150{}

      BP reading 1 - 2/17/2026 1:30 pm-  * Diastolic= 95, *Systolic = 130{}

       

      In this case, should we qualify the patient in numerator?

       

      Thanks,

      Ramya

       

       

       

       

            Assignee:
            AIR EC eCQM Team
            Reporter:
            Ramya Khasnis
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: