EC eCQMs - Eligible Clinicians
-
Resolution: Unresolved
-
Moderate
-
None
-
None
-
Ramya Khasnis
-
Spectramedix
-
CMS0122v12
-
Numerator calculation
Hi there,
We are submitting CMS 122 measure for MSSP program. We have 2 records for HbA1c test,
One record is for test performed with datetime e.g. patient had HBA1c test on 12/04/2024 10:30 am.
Another record with the results for test, but this record only captures the date no time e.g. patient had HbA1c test on 12/04/2024 with results 7.2
So according to measure when we do most recent record for HbA1c test if we consider the Hours and minutes of the test record 1 is latest but does not have any result. So patient will be numerator compliant. Do in reality the test result is < 9.0
So, can we consider the most recent records of a day. So patient will not be numerator compliant.
Please advise
Thanks,
Ramya