Hello,
I'm dealing with a situation in CMS135 (Heart Failure: ACEI or ARB or ARNI Therapy) where the numerator (NUM) calculation is affected by the medication’s relevantPeriod, specifically when a stop date is not defined in the EHR data. This is common when medications are added to the medication list without explicitly setting an end or stop date, as often happens in real-world clinical settings.
Question:
1. Does relevant period always require a defined high value?
2. Can the high value be set as NULL?
I am attaching 2 QRDA1 that are generated without defining the medication stop time in the EHR and both of these fall into DENOM only for CMS135v12
No stop 1:
QRDA_I_Hollis_Jones_nostop135.xml
No stop 2 (UNK)
QRDA_I_Hollis_Jones_unkstop.xml