      Thank you for your questions.

      The history code of Z86.79 for Afib/Flutter (personal history of other diseases of the circulatory system) is not included in the value set of Atrial Fibrillation/Flutter (2.16.840.1.113883.3.117.1.7.1.202) because this code is too broad to represent concepts of disorders for atrial fibrillation/ flutter only. We recommend mapping to either of the following 2 codes if the patient had chronic atrial fib condition:

      Code: I48.20

      Descriptor: Chronic atrial fibrillation, unspecified

      Code: 425615007

      Descriptor: Chronic atrial flutter (disorder)


      The LOS <= 120 days is a standard criteria included in most inpatient hospital eCQMs. STK and VTE eCQMs have this criteria to align the eCQM with the chart-based STK and VTE measures. We hope this helps.
      Show
      Thank you for your questions. The history code of Z86.79 for Afib/Flutter (personal history of other diseases of the circulatory system) is not included in the value set of Atrial Fibrillation/Flutter (2.16.840.1.113883.3.117.1.7.1.202) because this code is too broad to represent concepts of disorders for atrial fibrillation/ flutter only. We recommend mapping to either of the following 2 codes if the patient had chronic atrial fib condition: Code: I48.20 Descriptor: Chronic atrial fibrillation, unspecified Code: 425615007 Descriptor: Chronic atrial flutter (disorder) The LOS <= 120 days is a standard criteria included in most inpatient hospital eCQMs. STK and VTE eCQMs have this criteria to align the eCQM with the chart-based STK and VTE measures. We hope this helps.
    • CMS0108v10
    • Patient's are not meeting the numerator for VTE

      1. We are seeing patients admitted to the hospital with home medication of Apixaban 5mg twice daily, with a history of Afib/Flutter. Although the Afib/Flutter had not been diagnosed during this encounter, the patient states they had been diagnosed in the past at another hospital. They are coded with Z86.79 for Afib/Flutter (personal history of other diseases of the circulatory system). These patients are falling out of the numerator because Z codes are not included in the Value Sets. Why are the Z codes excluded from the VTE Value Set?
      2. Why is the length of stay less than or equal to 120 days for all eCQM measures Initial Population