OQR eCQMs - Outpatient Quality Reporting
-
Resolution: Answered
-
Moderate
-
None
-
None
-
CMS0996v3
The newly released 2023 eCQM for OP-40:
There is Denominator Exclusion for an Allergy/Intolerance to Thrombolytics and then an Adverse Event to Thrombolytics where the Medication value set "Thrombolytic Medications" is to be used, and a "type" is to be entered from "Adverse Reaction to Thrombolytics". Is the datatype for both of the above QDM: Allergy/Intolerance datatype? This datatype does have an attribute called "Type" but the list doesn't have specifics like in the value set valueset "Adverse reaction to thrombolytics" (2.16.840.1.113762.1.4.1170.6)
Code | Description | Code System | Code System Version | Code System OID | TTY |
293571007 | Streptokinase adverse reaction (disorder) | SNOMEDCT | 2021-09 | 2.16.840.1.113883.6.96 | FN |
293572000 | Urokinase adverse reaction (disorder) | SNOMEDCT | 2021-09 | 2.16.840.1.113883.6.96 | FN |
293573005 | Alteplase adverse reaction (disorder) | SNOMEDCT | 2021-09 | 2.16.840.1.113883.6.96 | FN |
293574004 | Anistreplase adverse reaction (disorder) | SNOMEDCT | 2021-09 | 2.16.840.1.113883.6.96 | FN |
with these codes