Hi Team,
We have a query related to numerator condition:
OR: $NoVTEProphylaxisPatientRefusal <= 1 day(s) starts after or concurrent with start of "Occurrence A of Encounter, Performed: ICU Admission or Transfer"
$NoVTEProphylaxisPatientRefusal =
◦Union of:
◾"Medication, Administered not done: Patient Refusal" for "Low Dose Unfractionated Heparin for VTE Prophylaxis"
◾"Medication, Administered not done: Patient Refusal" for "Low Molecular Weight Heparin for VTE Prophylaxis"
◾"Medication, Administered not done: Patient Refusal" for "Injectable Factor Xa Inhibitor for VTE Prophylaxis"
◾"Medication, Administered not done: Patient Refusal" for "Warfarin"
◾"Medication, Order not done: Patient Refusal" for "Low Dose Unfractionated Heparin for VTE Prophylaxis"
◾"Medication, Order not done: Patient Refusal" for "Low Molecular Weight Heparin for VTE Prophylaxis"
◾"Medication, Order not done: Patient Refusal" for "Injectable Factor Xa Inhibitor for VTE Prophylaxis"
◾"Medication, Order not done: Patient Refusal" for "Warfarin"
◾"Device, Applied not done: Patient Refusal" for "Intermittent pneumatic compression devices (IPC)"
◾"Device, Applied not done: Patient Refusal" for "Venous foot pumps (VFP)"
◾"Device, Applied not done: Patient Refusal" for "Graduated compression stockings (GCS)"
◾"Device, Order not done: Patient Refusal" for "Intermittent pneumatic compression devices (IPC)"
◾"Device, Order not done: Patient Refusal" for "Venous foot pumps (VFP)"
◾"Device, Order not done: Patient Refusal" for "Graduated compression stockings (GCS)"
The patient has got data for Device, Applied (Not Done: Patient Refusal) as well as Device, order (Not Done: Patient Refusal) as per below:
Device, Applied (Not Done: Patient Refusal) date - (20180808 17:53)
ICU date - (20180808 18:07) and
Device, order (Not Done: Patient Refusal) date - (20180808 18:07)
In the above case "Device, Applied (Not Done: Patient Refusal)" date is before ICU date AND date of Device, order (Not Done: Patient Refusal) is same as the ICU start date .
Kindly confirm if the patient should be Numerator complaint or not.