EH/CAH eCQMs - Eligible Hospitals/Critical Access Hospitals
-
Resolution: Answered
-
Moderate
-
Mismatch between human readable QDM list and underlying entries for Not Done medication order
-
John Mahoney
-
-
CMS100v4/NQF0142
-
CMS100v4 lists 3 data elements related to Medication Order: Aspirin ingredient specific, the order and the 2 reasons for the order not done in the Data Criteria itemized list section
<item>"Medication, Order: Aspirin ingredient specific" using "Aspirin ingredient specific RXNORM Value Set (2.16.840.1.113762.1.4.1021.3)"</item>
<item>"Medication, Order not done: Medical Reason" using "Medical Reason SNOMEDCT Value Set (2.16.840.1.113883.3.117.1.7.1.473)"</item>
<item>"Medication, Order not done: Patient Refusal" using "Patient Refusal SNOMEDCT Value Set (2.16.840.1.113883.3.117.1.7.1.93)"</item>
However there are only 2 substance administration entries in the measure XML, 1 for the patient refusal reason and 1 for the medical reason refusal. I do not find the Medication Order entry that does not contain the the actionNegationInd=true which I assume is what would provide the 3 entries in the Data Criteria section.
In summary, I see 3 entries for this valueset (ordered and 2 reasons) but only see 2 documented in the substance administration entries.
Are we to document the Medication Order if it was ordered?
- relates to
-
CQM-1812 Global use of ingredient specific value sets?
- Closed