Value set crosswalk causing variations in expectations

XMLWordPrintable

    • Icon: EH/CAH eCQMs - Eligible Hospitals/Critical Access Hospitals EH/CAH eCQMs - Eligible Hospitals/Critical Access Hospitals
    • Resolution: Resolved
    • Icon: Minor Minor
    • Measure, ValueSet
    • None
    • Hide
      Thank you for your question. This issue has been reviewed for an existing Jira ticket-CQM-1713. As part of the 2016 Annual Update these value sets will be reviewed to make certain the appropriate codes are in each value set.
      Show
      Thank you for your question. This issue has been reviewed for an existing Jira ticket- CQM-1713 . As part of the 2016 Annual Update these value sets will be reviewed to make certain the appropriate codes are in each value set.
    • CMS188v5/NQF0147
    • Several RxNorm codes within the Med, Active: Systemic Corticosteroid/Prednisone Therapy value set cause the patient to evaluate positively for the CMS 188 DEN EXCL logic, instead of DEN EXCEP where the data element is present.

      Codes within DEN EXCEP Med, Active: Systemic Corticosteroid/Prednisone Therapy value set crosswalk with codes in DEN EXCL Med, Active: Immunosuppressive Therapy (e.g., RxNorm 312617: Prednisone 5mg Oral Tablet, along with many other codes). Depending on which code is present in a patient's profile the patient will evaluate in different ways.