102460003 is required by the Procedure Intolerance template, but since it isn't in the valueSet 2.16.840.1.113883.3.88.12.3221.6.2, there is no way to create a valid document including this template.
Note, this will likely also be the case for the affected templates listed in the Description of this ticket, but I have only been testing our Procedure Intolerance.
This is related to JIRA ticket QRDA -73 and the HL7 QRDA I R3 DTSU Comment http://www.hl7.org/dstucomments/showdetail_comment.cfm?commentid=724. It is being logged again, since this prevents valid QRDA documents from being created with these templates for R2 or R3 of the QRDA I IG. This would affect the CMS documents for 2015 and 2016 reporting years, since they are conformant to these HL7 IGs.
The affected templates (we noticed this for the Procedure Intolerance template, but most of the Intolerance templates are affected) need to be changed to require a value listed in valueSet 2.16.840.1.113883.3.88.12.3221.6.2, or the valueSet needs to include the value 102460003.