URGENT: Request for guidance on timing operator logic - CQM 125v3 and v2 - Breast Cancer screening -

XMLWordPrintable

    • Icon: Defect Defect
    • Resolution: Answered
    • Icon: Minor Minor
    • None
    • Operator Logic
    • None

      Let's take example of CMS125v3 or v2
      In the header, Numerator description:
      “Women with one or more mammograms during the measurement period or the year prior to the measurement period

      In Population criteria
      Numerator =
      AND: "Diagnostic Study, Result: Mammogram (result)" <= 12 month(s) ends before or during "Measurement Period"

      CMS125v4 the logic has been changed and is correct
      • Numerator =
      o AND: "Diagnostic Study, Performed: Mammogram" < 24 month(s) ends before end of "Measurement Period"
      But CMS125v3 which has <= 12 month(s) ends before or during "Measurement Period" may be incorrect if we use the timing relationship guidance from “ActRelationshipType code system”, available at: http://www.hl7.org/v3ballot/html/infrastructure/vocabulary/ActRelationshipType.html” which states ‘ends before or during’ timing relationship as “A relationship in which the source act terminates before the target act terminates”.

      Please provide guidance as how to interpret ‘ends before or during "Measurement Period"’ with a time constraint “<= 12 months” and still be consistent with header numerator description of “during the measurement period or the year prior to the measurement period” for CMS125v3

      Similar logic guidance would be required for CMS124v3, CMS130v3