XMLWordPrintable

    • Type: Question
    • Resolution: Answered
    • Priority: Minor
    • Component/s: CQL
    • None
    • MADiE
    • Not Applicable
    • CMS1154: Screening for Abnormal Glucose Metabolism in Patients at Risk of Developing Diabetes
    • QDM 5.6
    • QA impact for measure finalization
    • Yes
    • Yes

      Hi MADiE team,

       

      On the QA spreadsheets we received from NLM, they flagged a direct reference code error. It is functioning in MADiE as-is, but we are reaching out to see if there is a better approach to handling the DRC. In CMS1154, they requested that we remove the codesystem declaration for CDCREC. As far as I could find, CMS1154 is the only eCQM currently using a DRC from CDCREC. Is there a functionality set up within MADiE (or even CQL) that I am unaware of that requires a different logic setup for this codesystem?

       

      The logic currently includes:

      • Line 7: codesystem "CDCREC": 'urn:oid:2.16.840.1.113883.6.238'
      • Line 23: code "Asian": '2028-9' from "CDCREC" display 'Asian'

       

      Thank you in advance for any guidance you may be able to provide!

            Assignee:
            Cindy Lamb
            Reporter:
            Britt Kent
            Votes:
            0 Vote for this issue
            Watchers:
            6 Start watching this issue

              Created:
              Updated:
              Resolved: