Type:
Bug/Issue
-
Resolution: Deferred for Future Release
-
Priority:
Minor
-
Component/s: None
-
None
-
MADiE
-
QI-Core
-
CMS506FHIRSafeUseofOpioids
-
QI-Core 6.0.0
-
-
Yes
-
Yes
Hello - Currently, there are 10 cases showing as invalid. I have confirmed that the external validator (https://validator.fhir.org/) does not return these as error/fatals. All 10 share a common error, pasted here. Other case JSON commonalities are that they are all Condition Resource and QICore Condition Problems Health Concerns Profile, each case is DENEX testing per logic. Please review and share solution as this deck is selected to be submitted. All case Condition.category follow - QICore Condition Problems Health Concerns - QI-Core Implementation Guide v6.0.0
- Error: Slice 'Condition.category:us-core': a matching slice is required, but not found (from http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-condition-problems-health-concerns|6.0.0). Note that other slices are allowed in addition to this required slice
- case #'s:
- 48
- 45
- 42
- 41
- 40
- 33
- 32
- 26
- 21
- 4