Type:
Bug/Issue
-
Resolution: Resolved
-
Priority:
Major
-
Component/s: Export Files
-
MADiE
-
Not Applicable
-
Hospital Harm - Postoperative Respiratory FailureFHIR
-
1218FHIR
-
Not Applicable
-
#1 IPPFail - ObstetricalDiagnosis
-
Test case bundle fails to import into any server as the reference described above is not valid
-
Yes
In measure Hospital Harm - Postoperative Respiratory FailureFHIR
Select test case #1 and export as transaction.
All resources are given UUID ids, as expected.
All resource references use the UUID ids as expected except for the "encounter" reference in the "Condition" resource. It is still using the "human readable" ID from the test case in MADiE:
"encounter":
{ "reference": "Encounter/Encounter-WithPregnancyConditionDiagnosis" }
See attached zip file containing this single case export.