For CMS2, attached file for 52_Terri_Burke.xml
Entry section templateid root 2.16.840.1.113883.10.20.22.4.69 has code element with a nullFlavor rather than the screening loinc that should be there:
<code nullFlavor="NA" sdtc:valueSet="2.16.840.1.113883.3.600.2452" />
For CMS61, attached file for 12_Dean_Stevens.xml
Entry section templateid root 2.16.840.1.113883.10.20.24.3.38 has code element with a NullFlavor rather than the lab test loinc that should be there:
<code nullFlavor="NA" sdtc:valueSet="2.16.840.1.113883.3.600.872" />
For CMS139, attached file for 13_Katrina_Nash.xml
Entry section templateid root 2.16.840.1.113883.10.20.22.4.69 has code element with a NullFlavor rather than the screening loinc that should be there:
<code nullFlavor="NA" sdtc:valueSet="2.16.840.1.113883.3.464.1003.118.12.1028" />
For CMS139, attached file for 15_Lauren_Farmer.xml
Entry section templateid root 2.16.840.1.113883.10.20.22.4.69 has code element with a NullFlavor rather than the screening loinc that should be there:
<code nullFlavor="NA" sdtc:valueSet="2.16.840.1.113883.3.464.1003.118.12.1028" />
All 4 of these file import issues cause our QRDA category 3 file to fail certification because our numbers don't match what is expected.
- relates to
-
CYPRESS-937 Issue with Reason of care Loinc missing
- Closed