-
Question
-
Resolution: Done
-
Critical
-
Other
Hi David,
There is a mismatch in observation value calculation.
We need minimum value for observation i.e. 240. However cypress has reported value 285.
Please let us know how shall we proceed. The below enclosed is screenshot of error for your reference.
Regards,
Samruddhi
- is cloned by
-
CYPRESS-1116 Cypress_EH_CMS32V6_Clone
- Closed
- is duplicated by
-
CYPRESS-1133 Cypress Certification
- Closed
- relates to
-
CYPRESS-1264 Median Value calculation results for CMS 32v6 do not match expected
- Closed