Uploaded image for project: 'CYPRESS Issue Tracker'
  1. CYPRESS Issue Tracker
  2. CYPRESS-696

CMS-61 Patient 3 N HEART has Risk Category Assessment value as ST instead of PQ

XMLWordPrintable

    • Implementation Problem

      We are testing with Cypress 3.0 alpha 6. We have noticed that the CMS-61 patient 3 N HEART has a Risk Category Assessment template for a Framingham Score with a value of "12%" given as a string type (ST).

      Since this is a discrete value with units, it would be better to implement it using the physical quantity type (PQ). With PQ, we know which piece of the value is intended to be the value and which piece is intended to be the units. This makes evaluation against the HQMF measure spec practical. It is very difficult to evaluate this otherwise, without special handling on each unique case of units.

      Can you confirm if this is something that will be updated for the final version of Cypress used for certification this year?

            ssayer Samuel Sayer
            rzoellne@epic.com Ryan Zoellner (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: