Bug/Issue
-
Resolution: Resolved
-
Moderate
-
see possible workaround below
-
CMS0069v11
-
CMS0069v10
-
Cypress v7.0.2
I got the following error when creating a CVU+ product for CMS69v10. I have attached relevant screenshots and a QRDA 1 zip file containing my imported vendor patients.
Here is the error I get when I create the CVU+ product:
"Cypress encountered an internal error while building this measure. Please contact the Cypress team at https://github.com/projectcypress/cypress/issues, and include the text below:
undefined method `collect' for nil:NilClass Did you mean? collectionize on /lib/cypress/scoop_and_filter.rb:6:in `initialize'"
I opened issue "Unable to create test deck for CVU+ project #1737" at https://github.com/projectcypress/cypress/issues. But I have not gotten a response.
I came up with a possible workaround. I added a 2nd measure. So in addition to CMS69v10, I added CMS130v10 (colorectal screening) when creating CVU+ project. When I do this I do not get the above error.
Please let me know if there is a better solution for this. Thanks!