Uploaded image for project: 'CYPRESS Issue Tracker'
  1. CYPRESS Issue Tracker
  2. CYPRESS-2277

Filter with OID instead of individual SNOMED CT code

XMLWordPrintable

    • Icon: Question Question
    • Resolution: Resolved
    • Icon: Moderate Moderate
    • v6.2.0

      For CMS 127, one of the filter tests looks for SNOMED 293116002.  Usually this test is an OID. In previous years this code was associated with OID 2.16.840.1.113883.3.464.1003.199.12.1027.  When I used this OID to filter with I do received the correct patient and pass the test.  It is necessary to filter by the code or can we use this OID to pass the test?  

            dczulada David Czulada
            drubacha David (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved: