      Hi,

      Reporting period : 2020
      Nursing Facility Visit
      startdate :  11/3/2018 8:00

      stopdate : null

       https://ecqi.healthit.gov/sites/default/files/ecqm/measures/CMS131v8.html

      In this case cypress qualifies exclusion bucket.And I am checking its stopdate as not null in the measurement period,so qualifies Not met bucket.

      Is this valid?Should we add constraint on the stopdate in the measurement period .i.e., jan2020 to Dec2020.

      Please explain with example.