Question
-
Resolution: Answered
-
Moderate
-
Logic affecting more than 1 eCQM
When testing the C4 Cypress criteria using measure CMS113v6, all QRDA1 files are reporting the same error: "Provider specialties (282N00000X, 282N00000X) do not match expected value (282N00000X)" (Screenshot attached)
It looks like it is expecting the specialty code of 282N00000X and upon manually inspecting the file i am finding the matching codes within the QRDA1 files i am uploading. I am not sure if this is an issue within the Cypress validation algorithm or if there is an expected value missing from my QRDA1 document (Attached).
Please let me know if there is any additional detail needed.