Validation error for CMS-167 in cypress 3.1.0

XMLWordPrintable

    • Type: Bug/Issue
    • Resolution: Answered
    • Priority: Moderate
    • None
    • Implementation Problem

      Hi,
      While validating CAT 1 file for CMS-167 we are getting following error.

      Calculated value (0.0) for NUMER (3186154C-6A01-4FAF-A77F-B5233A3F078C) does not match expected value (1.0)
      below is numerator condition
      Numerator =
      AND: "Diagnostic Study, Performed: Macular Exam" satisfies all:
      (result: Level of Severity of Retinopathy Findings) during Occurrence A of $EyeCareEncounters
      satisfies any:
      (result: Macular Edema Findings Absent)
      (result: Macular Edema Findings Present).

      We think our file is satisfying above condition than not sure why cypress is failing this validation.

      Can you please look into this. Any help is appreciated.
      I am attaching both our generated file and cypress sample file for a given patient.