Cypress Expects Incorrect QRDA III Program Name

XMLWordPrintable

    • Type: Question
    • Resolution: Answered
    • Priority: Moderate
    • Logic affecting more than 1 eCQM

      Cypress 3.1.0 is evaluating the QRDA III CMS Program Name value incorrectly in the C2 (QRDA III) record sample test. It currently expects the Program Name for individual reporting to be MIPS, which is consistent with the draft 2017 Implementation Guide. Table 3 of the 2017 Final QRDA III Implementation Guide specifies that the program name should be MIPS_INDIV for individual submissions. Documents submitted in Cypress 3.1.0 with a program name of MIPS_INDIV have the following CMS warning:

      This id SHALL contain exactly one [1..1] @extension, which SHALL be selected from ValueSet CMS Program Name urn:oid:2.16.840.1.113883.3.249.14.101 STATIC (CONF:2233-711162).