CMS2v6 - One of the QRDA-1 Test Data is represented as Denom. Exclusion. Whereas it should meet the Numerator criteria

XMLWordPrintable

    • Other

      Cypress test data for CMS2v6 is imported in our application. One of the patient is meeting the Numerator criteria. However Cypress v3.1.0 is expecting that this same patient should meet the Denominator Exclusions criteria.

      After analyzing QDM data of the Cypress QRDA-I patient is actually meets the Numerator Criteria.
      The same test data is replicated in the Bonnie Testing Tool. Bonnie is also shows the that it should meet the Numerator criteria

      34_Katrina_George.xml - This is Cypress QRDA-I file
      19_CypressScenario_CMS2v6Test.xml - This is generated from Bonnie Testing Tool

      Test data of the Cypress need to fix.