Thank you Heather for providing measure number.
Upon preliminary review in MADiE, it is apparent that there are multiple versions of QDM and QICore related to CMS113. In particular, some have higher QICore version numbers than that provided on this ticket.
Melissa, before analysis will be initiated, please confirm the exact Measure names and versions of both pertinent QDM and QICore versions and pertinent test cases in both specified measures..
For example, preliminary review of NUMFail-CSecStarts1MinAfterLabor.json indicates:
a) Loinc 11884-4 Gestational age Estimated, effectiveDateTime: 2025-01-01T08:00:00.000+00:00, value: 38 weeks,
b) Snomed 20236002 Labor established (finding), effectiveDateTime: 2025-01-01T08:59:00.000+00:00,
c) Loinc 93857-1 Date and time of obstetric delivery, effectiveDateTime: 2025-01-01T08:00:00.000+00:00, valueDateTime: 2025-01-01T08:00:00.000+00:00,
d) Snomed 8715000 Hospital admission, elective (procedure), start: 2025-01-01T08:00:00.000+00:00, end: 2025-01-20T08:15:00.000+00:00
e) ICD10 10D00Z0 for Extraction of Products of Conception, High, Open Approach, start: 2025-01-01T09:00:00.000+00:00, end: 2025-01-01T09:15:00.000+00:00
Please clarify, the above would indicate that delivery of infant occurred at 0800, labor started 0859 and Csection at 0900-0915 ??? Also, you have not indicated the aligning QDM test case.
Thank you, PMuir eCQM Standards Team
Thanks to you and Yanyan. Will close the ticket.
PMuir MD eCQM Standards Team