Uploaded image for project: 'BONNIE MAT MADiE Issue Tracker'
  1. BONNIE MAT MADiE Issue Tracker
  2. BONNIEMAT-1400

Not getting expected results with Present on Admission Indicator

XMLWordPrintable

    • MADiE
    • FHIR R4
    • Severe Obstetric Complications
    • CMS1028
    • EncDx_ICD10Sepsis
    • I cannot finalize test cases for this CMS measure until we find a solution to this problem.
    • Show
      https://github.com/cqframework/clinical_quality_language/issues/1152
    • MADiE 1.1.7
    • Yes

      I am creating a numerator test case in MADIE for the Severe Obstetric ComplicationsFHIR measure.  The test case name is EncDx_ICD10Sepsis and the JSON code is attached in NotePad++ and Word format.  The IP and Denom are passing as expected.  However the numerator is not passing (see screenshot attached).  

      My CQL logic is pointing to a value set that I defined in the VSAC ("Present on Admission = No or Unable To Determine": 'http://cts.nlm.nih.gov/fhir/ValueSet/2.16.840.1.113762.1.4.1029.370').  Per the example on the FHIR website, the JSON test case points to  the url "http://hl7.org/fhir/us/qicore/StructureDefinition/qicore-encounter-diagnosisPresentOnAdmission" and the "system" : "https://www.cms.gov/Medicare/Medicare-Fee-for-Service-Payment/HospitalAcqCond/Coding". 

      Would you be able to troubleshoot why this case is not meeting the numerator?  

            Heather.Frideres Heather Frideres
            mparenzan@jointcommission.org Marilyn Parenzan
            Votes:
            0 Vote for this issue
            Watchers:
            12 Start watching this issue

              Created:
              Updated:
              Resolved: