Once the choice is made, the initiator shall send a confirmation notification to the facility which will be taking care of the patient. The confirmation notification shall contain the date and time when the patient will be transferred. The initiator shall also send cancel notifications to the facilities, which had not already declined the request.
2.3.1 Confirmation Notification
The Confirmation Notification transaction contains a single OSU^O51 message, where ORC-1 will be set to the code SC (status change), and ORC-5 will be set to the code SC (in process, scheduled).
2.3.2 Cancel Notification
The Cancel Notification transaction is different from the general Cancellation Request in the base 360X specification in that there is no response expected. It contains a single OSU^O51 message, where ORC-1 will be set to the code DC (discontinue), and ORC-5 will be set to the code CA (cancelled).
2.4 Sending current information at time of discharge
...