[MADIE-2090] Modify Current Test Cases in Measure Created: 11/18/24 Updated: 12/02/24 Resolved: 12/02/24 |
|
Status: | Closed |
Project: | MADiE Issue Tracker |
Component/s: | None |
Affects Version/s: | None |
Fix Version/s: | None |
Type: | Bug/Issue | Priority: | Major |
Reporter: | Abdullah Rafiqi | Assignee: | Chandra Bartleman (Inactive) |
Resolution: | Resolved | Votes: | 0 |
Labels: | Measure, TestData | ||
Remaining Estimate: | Not Specified | ||
Time Spent: | Not Specified | ||
Original Estimate: | Not Specified |
Attachments: |
![]() ![]() ![]() ![]() ![]() |
Tool: | MADiE |
Tool Version: | Not Applicable |
Measure/Library Title: | Hospital Harm - Severe Hyperglycemia |
Measure/Library URL: | https://madie.cms.gov/measures/671257c8a8155344db7a80cb/edit/details/ |
CBE Number: | 3533e |
Measure Model: | QDM/CQL |
Test Case Name(s): | DENEXFail - GlucoseInterstitialFluidResult999 |
Test Case URL(s): | https://madie.cms.gov/measures/671257c8a8155344db7a80cb/edit/test-cases/671257c8a8155344db7a80be |
Help Desk Use Only Labels: | DEV |
Submitter Resolution Confirmed: | Yes |
Description |
I currently do not have the ability to modify certain test cases in our Hospital Harm - Severe Hyperglycemia measure. Currently trying to modify a test case in the measure and getting a Validation failed for object='testCase'. Error count:1 error message. |
Comments |
Comment by Chandra Bartleman (Inactive) [ 12/02/24 ] |
Thank you for confirming the workaround was successful for you. This can impact Denominator, Numerator and Measure Populations with observations. Here is the Known Issue added on 11/20/24: QDM Measures: For Ratio and Continuous Variable measures, in test cases Workaround: Remove the observation expected value by zeroing out the |
Comment by Abdullah Rafiqi [ 12/02/24 ] |
The workaround successfully resolved the issue for that specific test case. Going forward, for each affected test case, will a workaround be necessary only for the reference value observation of the denominator, or will similar modifications be required for the numerator as well? Thanks |
Comment by Shardae Sims [ 12/02/24 ] |
Good morning, I am following up on Abdullah behalf, the measure team will confirm today. Thanks! |
Comment by Chandra Bartleman (Inactive) [ 12/02/24 ] |
Abdullah, We have not heard from you since we provided a response on 11/20. This ticket will be closed at the end of the day today if we have not received a response from you. 11/20 message: The team has identified a workaround to resolve the error message you continue to receive. It is believed to stem from certain test cases that were imported from Bonnie where the reference value for observations is not being set when imported. To resolve the error message for the test case DENEXFail - GlucoseInterstitialFluidResult999, 1.) remove the Denominator Observation expected value , 2.) set Denominator expected value to 0 to make the Denominator Observation disappear, 3.) then reset Demoninator expect value back to 1 to make the Denominator Observation reappear, 4.) and then add back the expected value of 3 for the Denominator Observation, and 5.) save. This corrects the reference value and should allow you to save any changes. Does this solution work for you? Please confirm. |
Comment by Chandra Bartleman (Inactive) [ 11/25/24 ] |
Abdullah, We have not heard from you. Can you please review the workaround sent to you on 11/20/2024 and confirm this resolves the error you are receiving. Sincerely, |
Comment by Chandra Bartleman (Inactive) [ 11/20/24 ] |
Good morning Abdullah, The team has identified a workaround to resolve the error message you continue to receive. It is believed to stem from certain test cases that were imported from Bonnie where the reference value for observations is not being set when imported. To resolve the error message for the test case DENEXFail - GlucoseInterstitialFluidResult999, 1.) remove the Denominator Observation expected value , 2.) set Denominator expected value to 0 to make the Denominator Observation disappear, 3.) then reset Demoninator expect value back to 1 to make the Denominator Observation reappear, 4.) and then add back the expected value of 3 for the Denominator Observation, and 5.) save. This corrects the reference value and should allow you to save any changes. Does this solution work for you? Please confirm. |
Comment by Chandra Bartleman (Inactive) [ 11/18/24 ] |
Thank you for confirming that you updated the Improvement Notation to one of the available options in the dropdown, but are still receiving an unexpected error message. The measure package, your most recent screen shots, the specific updates you are attempting and the Measure and Test Case URLs have been shared with the MADiE team and are being researched. The ticket will be updated as more information becomes available. |
Comment by Abdullah Rafiqi [ 11/18/24 ] |
I’m encountering 400 errors when attempting to modify anything in the test case, particularly when trying to change the lab result quantity to 600 mg/dL or update the title or description of the test case. I've added more screenshots |
Comment by Chandra Bartleman (Inactive) [ 11/18/24 ] |
Abdullah, Now that the Improvement Notation section is updated, are you still receiving a 400 error or is a different error generated (400, 403, 500)? Can you describe the exact steps you are taking and where in the steps you receive the error? What specific modification to the test case are you attempting?
|
Comment by Abdullah Rafiqi [ 11/18/24 ] |
The issue persists even after updating the improvement notation. |
Comment by Chandra Bartleman (Inactive) [ 11/18/24 ] |
Abdullah, Did updating the Improvement Notation resolve this ticket issue as well? |
Comment by Abdullah Rafiqi [ 11/18/24 ] |
I’ve attached the measure package and included a screenshot of the DevTool window. The action triggers an error with code 400. |
Comment by Chandra Bartleman (Inactive) [ 11/18/24 ] |
Good morning Abdullah, Can you please attach the measure package for Hospital Harm - Severe Hyperglycemia to this ticket? The team will begin researching your inquiry upon receipt of the measure package. Also, can you please look to see if you can capture any error messages that might be generated when performing the following steps and provide a screenprint of the error you are receiving? 1. Prior to performing the desired action in MADiE, right click and select 'Inspect'. Sincerely, |
Comment by MADiE Team [ 11/18/24 ] |
Thank you for submitting your bug/issue to the MADiE team. This ticket has been assigned to a team member. Please review the MADiE Ticket Submission Guidance on the Training & Resources tab under the MADiE Helpful Links heading on the public website (https://www.emeasuretool.cms.gov/training-resources) and attach supporting documentation as directed in the guide. Populating all applicable fields while creating the ticket will assist the MADiE team when processing this ticket. |