[CYPRESS-303] ICD10 code only appearing in CMS69 Created: 12/26/13  Updated: 06/20/18  Resolved: 03/17/14

Status: Closed
Project: CYPRESS Issue Tracker
Component/s: None

Type: Question Priority: Blocker
Reporter: mahesh (Inactive) Assignee: Kevin Larsen (Inactive)
Resolution: Delivered Votes: 1
Labels: QRDA-I, TestData, ValueSet

Attachments: JPEG File screenshot-1.jpg    
Issue Links:
Cloners
clones CYPRESS-230 ICD 10 dataset issue in CMS69 Closed
Solution:  Vendors who wish to test CMS69 may choose any code from the "Pregnancy Dx" value set, however this measure MUST be tested in isolation from all other measures. This guidance is being confirmed with ONC and the issue will be closed once we have final confirmation.
Previous Issue Type: Value Sets

 Comments   
Comment by Kevin Larsen (Inactive) [ 03/17/14 ]

This is guidance is correct and in accordance to what was given on our call.

Comment by Timothy Bennett (Inactive) [ 03/12/14 ]

Can you guys please issue some guidance to the ATLs on how EHRUTs should work around this issue to demonstrate compliance?

Comment by mahesh (Inactive) [ 01/18/14 ]

Thanks Samuel for your help. I will watch this space.

M

Comment by Samuel Sayer (Inactive) [ 01/17/14 ]

We discussed the issue with ONC, and they would like to us to do some more research into the proposed guidance before it is official. I will update this issue once we have final guidance from ONC

Comment by Samuel Sayer (Inactive) [ 01/14/14 ]

We will be discussing this issue at the Cypress Tech Talk today at 1pm EST. You can register to attend by going to https://www4.gotomeeting.com/register/238584575. I will post the proposed guidance after the talk is over.

Comment by Samuel Sayer (Inactive) [ 01/10/14 ]

I don't have any guidance at the moment, but I will bring this up at our next meeting early next week. I will get you an answer as soon as I can.

Comment by mahesh (Inactive) [ 01/09/14 ]

Thanks Samuel

We are going for certification in couple of weeks, what do you think we should do?

We donot support ICD10 in our system and there is one patient with ICD-10-CM: O62.3 as Pregnancy Dx. If we use corresponding snomed code it passes Cypress. Do you think it is ok as long as Cypress shows ZERO errors? Similar issue is with Smoking status, it works with other corresponding snomed codes.

Mahesh

Comment by Samuel Sayer (Inactive) [ 01/09/14 ]

Mahesh,

Sorry we didn't get back to you sooner. This is known issue in Cypress. It is due to code crosswalk that happens between value sets. In order to prevent this problem, we have had to whitelist/blacklist certain codes. Unfortunately for this measure, all the codes have been blocked except for an ICD-10 code. We are working with ONC to provide interim guidance while we tackle this difficult issue. Thank you for your patience.

-Sam

Comment by mahesh (Inactive) [ 12/31/13 ]

Here is one more example where there is different types of coding are enforced. For measure 0004 there are 4 encounters for BH_Adult patient, 3 are using only CPT and one is using SNOMED. to populate the data do we have to support different multiple coding standards for Encounter? i.e. Both CPT and Snomed?

Comment by mahesh (Inactive) [ 12/26/13 ]

Please see the scrrenshot. It has only ICD10 for diagnosis. We support only ICD9 and SNOMED. How to handle this?
Diagnoses

Description Codes Time Status Results Fields
Diagnosis, Active: Pregnancy Dx (Code List: 2.16.840.1.113883.3.600.1.1623) ICD-10-CM: O62.3
March 1st, 2012 10:00 - March 1st, 2012 11:00 active

This test data has only ICD 10 whereas we donot capture ICD10.

Mahesh

Comment by mahesh (Inactive) [ 12/26/13 ]

Please see the test data, it has only ICD10 code. We donot have support for ICD10, how to go about this.