[CQM-6209] Follow up on Clarification for the Numerator criteria Logic of CMS816 (Hospital Harm - Severe Hypoglycemia ) Created: 07/06/23 Updated: 07/20/23 Resolved: 07/20/23 |
|
Status: | Closed |
Project: | eCQM Issue Tracker |
Component/s: | None |
Type: | Hosp Inpt eCQMs - Hospital Inpatient eCQMs | Priority: | Moderate |
Reporter: | Shravanthi S (Inactive) | Assignee: | Joelencia Leflore |
Resolution: | Answered | Votes: | 0 |
Labels: | None |
Solution: | Thank you for your inquiry specific to CMS816v3 Hospital Harm – Severe Hypoglycemia.
Regarding question 1: In your testcase scenario, the numerator is met. Although there is a glucose test with a result of 37 mg/dL on 5/2 at 11:00 followed by a glucose test with a result of >80 within 5 minutes (which is not a harm), there were 3 subsequent hypoglycemic events that qualify as a harm during the encounter. Regarding question 2: Your understanding is correct. ‘Glucose Test with Result Less Than 40’ returns the 4 labs you have listed, and the ‘Low Glucose Test Followed By Glucose Test Result Greater Than 80’ returns the 1 lab (2345-7) since it is followed by the glucose test >80 within 5 minutes. Regarding your statement on what is returned with the [LowGlucoseTest.id in "Low Glucose Test Followed By Glucose Test Result Greater Than 80".id] logic: To clarify, this piece of logic is part of the following definition which is used to help evaluate if the numerator is met: Severe Hypoglycemic Harm Event: "Glucose Test with Result Less Than 40" LowGlucoseTest where not ( LowGlucoseTest.id in "Low Glucose Test Followed By Glucose Test Result Greater Than 80".id ) The intent is to capture and return glucose lab tests <40 that are not followed by a glucose lab test >80 (within 5 minutes). Using your scenario, the three lab tests that meet this criteria are returned: 40858-3, 41651-1, 1557-8, as seen in this excerpt from the Bonnie: [Laboratory Test, Performed: Glucose Lab Test Mass Per Volume START: 05/02/2012 11:10 AM STOP: 05/11/2012 11:30 PM CODE: LOINC 40858-3, Laboratory Test, Performed: Glucose Lab Test Mass Per Volume START: 05/02/2012 11:15 AM STOP: 05/11/2012 11:30 PM CODE: LOINC 41651-1, Laboratory Test, Performed: Glucose Lab Test Mass Per Volume START: 05/02/2012 11:20 AM STOP: 05/11/2012 11:30 PM CODE: LOINC 1557-8] Your understanding of the purpose of the “in” operator is correct. The “in” operator in the “( LowGlucoseTest.id in "Low Glucose Test Followed By Glucose Test Result Greater Than 80".id )” condition evaluates if a lab test in the ‘LowGlucoseTest’ list is also “in” the ‘Low Glucose Test Followed By Glucose Test Result Greater Than 80’ list. |
Solution Posted On: | |
2024 Reporting Period Hosp Inpt eCQMs: |
CMS0816v3
|
Impact: | Delaying the Product development timeline and impacting the delivery of the release. |
Description |
Hi team, We have a follow up question to the solution provided for this ticket - https://oncprojectracking.healthit.gov/support/browse/CQM-6171
Please consider the below scenario:
Can you please help us understand the Numerator qualification in this scenario and if our understanding on the in operator is correct. |
Comments |
Comment by Joelencia Leflore [ 07/20/23 ] |
We apologize for the delay in providing a response for your question. We continue to investigate the issue noted in your ticket and will provide a response as soon as we are able. Thank you for your continued patience. |
Comment by Joelencia Leflore [ 07/13/23 ] |
We continue to investigate the issue noted in your ticket and will provide a response as soon as we are able. Thank you for your patience. |
Comment by Joelencia Leflore [ 07/06/23 ] |
Thank you for submitting your question. We will review your ticket and provide a response as soon as possible. |