[CQM-2836] ePC-01 patients on the ePC 2017 report meeting numerator due to ICD code 10907ZC Created: 09/27/17  Updated: 04/30/19  Resolved: 04/30/19

Status: Closed
Project: eCQM Issue Tracker
Component/s: ValueSet

Type: EC eCQMs - Eligible Clinicians Priority: Moderate
Reporter: Brian Stephens (Inactive) Assignee: Joelencia Leflore
Resolution: Done Votes: 1
Labels: CQM, Measure, ValueSet

Contact Name: Brian Stephens
Contact Email: brian.stephens@nkch.org
Contact Phone: 8166915492
Institution/Name: North Kansas City Hospital
Solution: ​Thank you for your query! It seems like it is not so much of a code issue but more of an implementation issue i.e: how the measure logic is implemented at your organization. The way it is implemented currently it is failing to use the timing operator which is a part of the "medical induction" part of the neumerator logic:

 

•Union of:
◦"Procedure, Performed: Medical Induction of Labor"
◦"Procedure, Performed: Artificial Rupture of Membranes"
◦"Medication, Administered: Oxytocin"
◦"Medication, Administered: Dinoprostone​
 

•<= 24 hour(s) starts before start of ("Assessment, Performed: Labor" starts during Occurrence A of $EncounterInpatient
Solution Posted On:
2017 Reporting Period EH eCQMs:
CMS113v5/NQF0469
Impact: Until there is a distinction between Natural or Artificial opening with this code, our facility will continue to have patients meet the numerator when they should not.
Comment Posted On:

 Description   

The code 10907ZC (Drainage of Amniotic Fluid, Therapeutic from Products of Conception, Via Natural or Artificial opening) is causing patients to meet the numerator when in fact the patient had labor before medical induction of labor occurred. However when coded, the patients are coded with 10907ZC and therefore meet the numerator when they should not.


Generated at Sun Aug 31 08:14:53 UTC 2025 using Jira 10.3.8#10030008-sha1:cdaed80cecc964184c5b19b002388d56f96e274e.