Uploaded image for project: 'CYPRESS Issue Tracker'
  1. CYPRESS Issue Tracker
  2. CYPRESS-484

QRDA Cat 1 file for test patient "STROKE_ADULT B" is missing negation code

XMLWordPrintable

    • Icon: Bug/Issue Bug/Issue
    • Resolution: Delivered
    • Icon: Minor Minor
    • Implementation Problem

      When looking at the HTML file for the test Cypress patient "STROKE_ADULT B" they have an entry in the "Communication From Patient To Providers" section that has a "Negation Reason" code of "105480006". The code "105480006" does not appear anywhere in the QRDA Cat 1 XML file for the patient "STROKE_ADULT B".

      The absence of this negation code causes this patient to not fall in the Numerator for measure CMS 107 v3 as expected, because the Numerator is looking for a "Communication: From Patient to Provider" element with a code from the "Written Information Given" value set and a negation code from the "Patient Refusal" value set.

      Attached are the HTML and QRDA Cat 1 files for the "STROKE_ADULT B" patient that were downloaded from a Cypress 2.5.1 website.

            jcolbert312 Jean Colbert (Inactive)
            tryabin Thomas Ryabin (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

              Created:
              Updated:
              Resolved: