eCQM 130 FOBT and sDNA logic

XMLWordPrintable

    • Type: EC eCQMs - Eligible Clinicians
    • Resolution: Answered
    • Priority: Moderate
    • Component/s: None
    • None
    • Koan Health
    • Hide
      Thank you for your inquiry about CMS130v13 (2025 performance period). Applicable screenings that meet the numerator criteria may include the following: Fecal Occult Blood Test (FOBT), Stool DNA with Fecal Immunochemical Test (FIT), Flexible Sigmoidoscopy, CT Colonography, or Colonoscopy. These screenings may count towards the numerator when performed within the required timeframe and documented via QDM datatypes and codes below. A result is not required for the flexible sigmoidoscopy, colonoscopy, or CT colonography. A "non-null" result is required for screening options such as FOBT and Stool DNA with FIT laboratory tests. An insufficient sample may count towards the numerator since a non-null result can be interpreted as a result that is present in the electronic record in which any entry is acceptable; no specific value or code is required. Equivalent services can be mapped to the measure's value sets. If mapping is done, you should maintain documentation in case of a CMS audit.
       
      - "Laboratory Test, Performed" using a code from "Fecal Occult Blood Test (FOBT)" value set (2.16.840.1.113883.3.464.1003.198.12.1011)"
      - "Laboratory Test, Performed" using a code from "sDNA FIT Test" value set (2.16.840.1.113883.3.464.1003.108.12.1039)
      - "Procedure, Performed" using a code from "Flexible Sigmoidoscopy" value set (2.16.840.1.113883.3.464.1003.198.12.1010)
      - "Diagnostic Study, Performed" using a code from "CT Colonography" value set (2.16.840.1.113883.3.464.1003.108.12.1038)
      - "Procedure, Performed" using a code from "Colonoscopy" value set (2.16.840.1.113883.3.464.1003.108.12.1020)
       
      If you have questions about reading the measure specification or understanding data requirements, you may refer to the "Guide for Reading eCQMs" for additional guidance. If you have questions regarding implementing the measure, you may refer to the "Implementation Checklist for eCQM Annual Update" for additional guidance. These resources can be found in the eCQI Resource Center: https://ecqi.healthit.gov/ep-ec?qt-tabs_ep=ecqm-resources&global_measure_group=eCQMs. If you have questions regarding CMS quality program reporting requirements, please review the QPP website or contact the QPP Helpdesk at QPP@cms.hhs.gov.
      Show
      Thank you for your inquiry about CMS130v13 (2025 performance period). Applicable screenings that meet the numerator criteria may include the following: Fecal Occult Blood Test (FOBT), Stool DNA with Fecal Immunochemical Test (FIT), Flexible Sigmoidoscopy, CT Colonography, or Colonoscopy. These screenings may count towards the numerator when performed within the required timeframe and documented via QDM datatypes and codes below. A result is not required for the flexible sigmoidoscopy, colonoscopy, or CT colonography. A "non-null" result is required for screening options such as FOBT and Stool DNA with FIT laboratory tests. An insufficient sample may count towards the numerator since a non-null result can be interpreted as a result that is present in the electronic record in which any entry is acceptable; no specific value or code is required. Equivalent services can be mapped to the measure's value sets. If mapping is done, you should maintain documentation in case of a CMS audit.   - "Laboratory Test, Performed" using a code from "Fecal Occult Blood Test (FOBT)" value set (2.16.840.1.113883.3.464.1003.198.12.1011)" - "Laboratory Test, Performed" using a code from "sDNA FIT Test" value set (2.16.840.1.113883.3.464.1003.108.12.1039) - "Procedure, Performed" using a code from "Flexible Sigmoidoscopy" value set (2.16.840.1.113883.3.464.1003.198.12.1010) - "Diagnostic Study, Performed" using a code from "CT Colonography" value set (2.16.840.1.113883.3.464.1003.108.12.1038) - "Procedure, Performed" using a code from "Colonoscopy" value set (2.16.840.1.113883.3.464.1003.108.12.1020)   If you have questions about reading the measure specification or understanding data requirements, you may refer to the "Guide for Reading eCQMs" for additional guidance. If you have questions regarding implementing the measure, you may refer to the "Implementation Checklist for eCQM Annual Update" for additional guidance. These resources can be found in the eCQI Resource Center: https://ecqi.healthit.gov/ep-ec?qt-tabs_ep=ecqm-resources&global_measure_group=eCQMs . If you have questions regarding CMS quality program reporting requirements, please review the QPP website or contact the QPP Helpdesk at QPP@cms.hhs.gov .
    • CMS0130v14
    • CMS0130v13
    • CMS0130v12

      I'm writing to request clarification on the CMS130 eCQM measure logic for the 2026 reporting year, specifically regarding stool-based colorectal cancer screening tests.
       
      In reviewing the published CQL logic for CMS130, it appears that the numerator requires a non-null result for the following test types:
      • FOBT
      • sDNA / FIT-DNA
       
      Our understanding is that the logic does not allow the presence of a qualifying test code alone to satisfy the numerator. In other words, a record with the appropriate LOINC code, but with no associated result value, would not meet numerator criteria.
       
      We would appreciate written confirmation on the following points:
      1. For CMS130, does an FOBT require a non-null result in order to satisfy the numerator?
      2. For CMS130, does an sDNA test require a non-null result in order to satisfy the numerator?
      3. Is the presence of a qualifying code alone, without a result value, insufficient for numerator credit for these tests?
       
      We are asking because, in some client source data, we see qualifying codes present without populated result values, and we want to ensure our interpretation of the CMS specification is correct before advising clients on reporting requirements.

            Assignee:
            AIR EC eCQM Team
            Reporter:
            Nick Nguyen (Inactive)
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

              Created:
              Updated:
              Resolved:
              Solution Posted On: